Conserving Energy in Blast Freezers Using Variable Frequency Drives
| Title: | Conserving Energy in Blast Freezers Using Variable Frequency Drives |
| Author: | Kolbe, E.; Ling, Q.; Wheeler, G. |
| Abstract: | A stationary blast freezer processing 22-lb cartons of sardines in 19,000 pound lots was modified to improve efficiency and to conserve energy. Baffles were first added to produce uniform air flow. Maximum measured freeze times of 12.6 hours fell to 10.5 |
| Publisher: | Energy Systems Laboratory (http://esl.tamu.edu) |
| URI: | http://handle.tamu.edu/1969.1/6052 |
| Date: | 2004 |