Conserving Energy in Blast Freezers Using Variable Frequency Drives

Show full item record

Title: Conserving Energy in Blast Freezers Using Variable Frequency Drives
Author: Kolbe, E.; Ling, Q.; Wheeler, G.
Abstract: A stationary blast freezer processing 22-lb cartons of sardines in 19,000 pound lots was modified to improve efficiency and to conserve energy. Baffles were first added to produce uniform air flow. Maximum measured freeze times of 12.6 hours fell to 10.5
Publisher: Energy Systems Laboratory (http://esl.tamu.edu)
URI: http://handle.tamu.edu/1969.1/6052
Date: 2004

Files in this item

Files Size Format View
ESL-IE-04-04-08.pdf 148.6Kb application/pdf View/Open

This item appears in the following Collection(s)

Show full item record